IR mode testing confirms that a Smart Badge in the space is receiving the infrared room number signal from the Beam Mini correctly. Run this after installing a Beam Mini in IR mode to verify the signal coverage before leaving the site.
Before you begin
- Signed in to Kio Setup Manager with the Device Management role
- Beam Mini is installed in IR mode and within Bluetooth range of your mobile device
- A Smart Badge is present in the space and within line of sight of the Beam Mini's IR emitter
Steps
- Open the device detail view for the Beam Mini:
- Tap Devices > Nearby and select it from the list, or
- Tap Scan and scan the QR code on the device label
- Tap the actions menu and select Test IR.
- Kio Setup Manager connects to the Beam Mini over Bluetooth and initiates the IR signal test.
- Review the test result.
Test result states
| Result | Meaning | Action |
|---|---|---|
| Success | Smart Badge received the IR room number correctly | No action needed |
| Badge not detected | No Smart Badge was found in range during the test | Confirm a badge is present and within line of sight; retry |
| IR signal not received | Badge was detected but did not receive the room number | Adjust Beam Mini placement or IR emitter angle; retry |
What happens next
A successful test confirms the IR room number is being received by Smart Badges in the space. The room number transmitted by the Beam Mini appears in the device detail view telemetry under Room number.
If the test fails repeatedly, verify the Beam Mini is mounted so its IR emitter has clear line of sight across the area where badges will be present.