Configuring probes updates the probe assignments on a Temp Monitor Pro without changing the device's location or monitoring type. Use Configure Probes when you need to change which Storage Unit a probe monitors, update the Threshold Setting applied to a probe, or enter or correct a probe's serial number. A Temp Monitor Pro supports up to two probes, each assigned to its own Storage Unit and Threshold Setting.
This action is for the Temp Monitor Pro only; the Temp Monitor Lite has no external probes. To change the device's location, or to switch between Room and Storage Unit monitoring, use Reconfigure a Monitor instead.
Before you begin
- The Kio Setup Manager mobile app is installed on your mobile device and you are signed in. See Sign in to Kio Setup Manager (Temperature Monitoring).
- Bluetooth is turned on, your mobile device has an internet connection (Wi-Fi or cellular), and you are within Bluetooth range of the Temp Monitor Pro.
- You are assigned a Temperature Monitoring role with install access (Administrator, System Manager, or Facilities Manager) and the Kio Setup Manager installer role for your platform. See Temperature Monitoring user roles.
- The Storage Units and Threshold Settings you are assigning already exist in Temperature Monitoring.
- The probes are physically connected to the device.
Tip: Make sure Kio Setup Manager is updated to the latest version. Check for updates in the App Store (iOS) or Google Play (Android).
Steps
- Open Kio Setup Manager and tap Scan.
- When the Temp Monitor Pro appears in the scan list, tap it.
- On the Actions screen, tap Configure Probes.
- On the Configure connected probes screen, configure each connected probe. Next stays disabled until every connected probe is fully configured. For each probe:
- Tap Enter Probe Serial Number and enter the serial number printed on the probe's label, then submit it.
- Tap the Storage Unit row and select the Storage Unit this probe monitors. Confirm with Yes, Assign.
- Tap the Threshold Setting row and select the Threshold Setting for that Storage Unit.
- Tap Next when all connected probes are configured.
- Review the summary and tap Confirm.
Result
The updated probe assignments take effect immediately, and the affected Storage Units reflect the new configuration in Temperature Monitoring.
Note: If a Storage Unit stays in Data out of sync for more than 10 minutes after a Threshold Setting change, reconfigure the Monitor in Kio Setup Manager. See Reconfigure a Monitor.
If a probe is not in the list
If a probe does not appear as connected during configuration, confirm the probe cable is securely connected to the device before continuing. A disconnected probe sets the Monitor's status to Probe disconnected. See Troubleshooting: Probe disconnected.